VMware VCAP-Storage

VMware 3V0-23.25 Practice Test & Study Guide

Advanced VMware Cloud Foundation 9.0 Storage

Exam code
3V0-23.25
Questions
77
Updated
25 Nov 2026

What's in the 3V0-23.25 study guide

  • 77practice questions with answers
  • PDFread and print on any device
  • Test enginepractice and exam modes online
  • 90 daysof free updates
  • Instant access from My Account after payment
  • 90 days of free updates
  • Money-back guarantee – see conditions
  • Help by live chat or email

Price$35

Choose a format

Prices in USD. Downloads appear in My Account once your order is complete.

  • Instant access from My Account after payment
  • 90 days of free updates
  • Money-back guarantee – see conditions
  • Help by live chat or email
Free demo

3V0-23.25 sample questions

Check the style and quality of the material before you buy.

Question 1

A customer attaches an external Fibre Channel (FC) VMFS datastore to a VMware Cloud Foundation (VCF) workload domain for backup staging. The administrator must confirm that the datastore is visible to all hosts, and that path and device health alarms will trigger should a fabric link or path fail. Which action should the administrator take to verify this?

  • A. Run esxcli vsan storage list on each host to view VMFS datastore path status.  
  • B. In vCenter verify the external VMFS datastore connectivity, paths and multipath health.  
  • C. Execute storage.monitor.getStatus via VCF SDK to receive a consolidated health summary of all VMFS, vSAN and NFS datastores.  
  • D. Use esxcli fc adapter list followed by vmkfstools --inspectpaths to validate health for the VMFS LUN.

Answer: B

Question 2

An administrator is tasked with deploying a VMware Cloud Foundation (VCF) WorkloadDomain that meets the following requirements:• vSAN ESA as principal storage• RAID-6 with FTT=2• Support for Storage Traffic SeparationThe administrator is provided the following hardware to perform the task:• Four ESX hosts, each host contains:24 CPU cores96 GB memoryTwo 25GbE network NICs12 NVMe devices 4 TB each, connected to a single SATA/SAS/NVMe Tri-modecontrollerWhat four changes must the administrator make to the hardware beforedeploying the new Workload Domain? (Choose four.)

  • A. Increase the ESX host count to a minimum of seven.  
  • B. Increase the ESX host count to a minimum of six.  
  • C. Increase the CPU quantity on each host to a minimum 32.  
  • D. Increase the Tri-mode controller quantity on each host to two, with six NVMe devices connected to each.
  • E. Increase the network NICs on each host to minimum of four 25 GbE network NICs.  
  • F. Replace the network NICs on each host to a minimum of two 100 GbE network NICs.  
  • G. Increase the memory on each host to a minimum 128 GB.  
  • H. Replace the Tri-mode controller on each host with a dedicated NVMe controller.  

Answer: B,E,G,H

Question 3

An administrator has been tasked with suggesting storage models for a new VMware CloudFoundation (VCF) Private Cloud. The following information has been provided:• All existing implementations of VMware vSphere use the existing third-party block-basedstorage solution.• The block-based storage solution only has sufficient scale, capacity and IOPS to cater forthe new workload storage requirements.• There is a dedicated and highly resilient storage area network connecting hosts to theprovided block-based storage.• There are 5 existing hosts with enough CPU and RAM resources and resilient Host BusAdapters (HBAs) to cater for the new workload resource requirements only.• There is sufficient budget to purchase some hardware, however the solution must re-usethe existing hardware where possible.The administrator suggests the following high-level solution:• Single VCF Instance with a single Workload Domain.• Deploy 4 new servers to create a Management Domain.• Repurpose the 5 existing servers to create a single cluster in the Workload Domain.Which two storage models should the administrator recommend? (Choose two.)

  • A. iSCSI should be the supplemental storage solution for the VCF Workload Domain.  
  • B. iSCSI should be the principal storage solution for the VCF Management Domain.  
  • C. Fibre Channel should be the principal storage solution for the VCF Workload Domain.  
  • C. Fibre Channel should be the principal storage solution for the VCF Workload Domain.  
  • E. VMware vSAN should be the principal storage solution for the VCF Workload Domain.  

Answer: C,D

Question 4

An administrator has been tasked with adding supplemental storage to an existing VMware Cloud Foundation (VCF) Workload Domain. The supplemental storage will add capacity for backup data and ISO images without impacting the principal storage used for live production workloads. What should the administrator recommend meeting the requirement?

  • A. Migrate Management Domain storage to a new cluster.  
  • B. Increase the VMFS principal storage allocation.  
  • C. Attach additional NFS volumes or iSCSI datastores.  
  • D. Replace all existing datastores with NVMe devices.  

Answer: C

Question 5

An administrator is tasked with configuring the vSAN File Service to deliver NFS file shares for an Edge environment.Which three are required to deliver the service? (Choose three.)  

  • A. Create a dedicated port group for vSAN File Services in the DVS.  
  • B. If using an NSX-based network, ensure that MAC Learning is enabled.  
  • C. MAC Learning and Forged Transmits are disabled.  
  • D. Jumbo frames are enabled on the network and the DVS port group.  
  • E. Hosts connected to a DVS version 6.6.0 or later.  
  • F. vSAN Witness functionality is enabled on each VMkernel.  

Answer: A,B,E

Question 6

An administrator is presented with the following scenario:• 20 TB of additional storage is being requested by a VM application owner.• The application has high CPU/Memory requirements that can only be satisfied by thecurrent cluster the application runs in.• The application has high IOPS and bandwidth requirements to run properly.• The existing vSAN cluster only has 10 TB of unused capacity.• The hosts in the cluster have no additional NVMe slots left.• The administrator does not have permission to purchase additional hosts or re-assignhosts from other vSAN clusters.• Other vSAN clusters exist in the environment that can satisfy the requirement.Which vSAN feature should be used to fulfill this scenario?

  • A. vSAN HCI Mesh  
  • B. vSAN Data Protection  
  • C. vSAN File Services  
  • D. vSAN Stretched Clusters  

Answer: A

Question 7

An administrator is presented with the following scenario:• 20 TB of additional storage is being requested by a VM application owner.• The application has high CPU/Memory requirements that can only be satisfied by thecurrent cluster the application runs in.• The application has high IOPS and bandwidth requirements to run properly.• The existing vSAN cluster only has 10 TB of unused capacity.• The hosts in the cluster have no additional NVMe slots left.• The administrator does not have permission to purchase additional hosts or re-assignhosts from other vSAN clusters.• Other vSAN clusters exist in the environment that can satisfy the requirement.Which vSAN feature should be used to fulfill this scenario?

  • A. vSAN HCI Mesh  
  • B. vSAN Data Protection  
  • C. vSAN File Services  
  • D. vSAN Stretched Clusters  

Answer: A

Question 8

While creating a recovery plan that matches the business continuity plan, an administrator needs to add custom steps to the recovery plan. Which three custom steps are available? (Choose three.)

  • A. IP reconfiguration  
  • B. Create writable Storage Snapshots  
  • C. Top level commands  
  • D. Pause
  • E. Message prompt  
  • E. Message prompt  

Answer: C,E,F

Question 9

An administrator is managing a stretched vSAN ESA cluster where each site has threehosts.The following parameters apply to the storage policy being configured at the datastorelevel:• The policy is configured at the datastore level• Site disaster tolerance = Site mirroring - stretched cluster• Failures to tolerate = 1 failure - RAID-1 (mirroring)• Number of disk stripes = 1When inspecting some of the Virtual Machines (VMs), why do objects have 3 disk stripes?

  • A. ESA in RAID-1 always uses 3 stripes.  
  • B. Site mirroring has been configured.  
  • C. Each Virtual Machine has 3 objects.  
  • D. There is a policy configured at the Virtual Machine level.  

Answer: A

Question 10

An administrator is planning the deployment of a new VMware Cloud Foundation (VCF)Workload Domain. The storage design decisions for the solution are:• NFS• NVMe over RDMA• No local storage is available to the hostsWhat is the storage solution build order for the Workload Domain?

  • A. vSAN OSA as principal storage, then add NFS and NVMe over RDMA as supplemental storage. 
  • B. vSAN ESA as principal storage, then add NFS and NVMe over RDMA as supplemental storage. 
  • C. NVMe over RDMA as principal storage, then add NFS as supplemental storage.  
  • D. NFS as principal storage, then add NVMe over RDMA as supplemental storage.  

Answer: D

Why RealExamCollection is the best choice for VMware 3V0-23.25 exam preparation

Secure your position in a competitive IT industry

The VMware 3V0-23.25 certification is a strong way to demonstrate your understanding and ability. Our 3V0-23.25 questions & answers help you prepare for it, so you can secure your current position and move your career forward.

Reviewed by IT professionals

We keep our 3V0-23.25 practice questions up to date, with explanations. The questions and answers on RealExamCollection are reviewed by people with professional experience of VMware technologies.

One place to prepare

RealExamCollection brings together the material you need for the VMware 3V0-23.25 exam. Explanations are added to the questions to help you understand the logic behind them and prepare for other VMware exams.

Updated 3V0-23.25 questions & answers

We update the exam files regularly to add new questions. The date of the latest update is shown at the top of this page.

Free 3V0-23.25 demo before you buy

You can view sample 3V0-23.25 questions on this page before buying, to see the format and pattern of the material.

90 days of free updates

You are eligible for 90 days of free updates after buying the 3V0-23.25 exam. If the file is updated in that time, you can download the latest version from your account.

Ready to prepare?

VMware 3V0-23.25 · 77 questions

Choose a format