Winter Sale! Use this Coupon Code to get 20% OFF REC20

HP HPE6-A66 Dumps

HP HPE6-A66 Dumps PDF

Aruba Certified Design Associate Exam
  • 60 Questions & Answers
  • Update Date : July 11, 2024

PDF + Testing Engine
$65
Testing Engine (only)
$55
PDF (only)
$45

Why is Real Exam Collection the best choice for certification exam preparation?

Unlike other web portals, RealExamCollection.com is committed to give HP HPE6-A66 practice exam questions with answers, free of cost. To see the entire study material you need to sign up for a free account on RealExamCollection. A lot of customers all over the world are getting high grades by using our HPE6-A66 dumps. You can get 100% passing and money back guarantee on HPE6-A66 exam. Instant access to pdf files right after purchase.

A Central Tool to Help You Prepare for HP HPE6-A66 Exam

RealExamCollection.com is the final tuition basis for taking the HP HPE6-A66 exam. We strictly followed the accurate review exam questions and answers, which are regularly updated and reviewed by production experts. Our HP HPE6-A66 dumps experts from various well-known administrations are intellectuals and qualified individuals who have look over very important HP HPE6-A66 exam question and answer section to benefit you to realize the concept and pass the certification exam with good marks. HP HPE6-A66 braindumps is the best way to prepare your exam in just 1 day.

User Friendly & Easily Accessible on Mobile Devices

You can find extremely user friendly platform for HP exam. The main aim of our platform is to provide latest accurate, updated and really helpful study material. This material helps the students to study and pass the implanting and supporting HP systems. Students can get access to real exam questions and answers , which will available to download in PDF format right after the purchase. This website is mobile friendly for tester and gives the ability to study anywhere as long as internet data connection on your mobile device.

Get Instant Access to the Most Accurate & Recent Aruba Certified Design Associate Exam Questions & Answers:

Our exam database is frequently updated all over the year to contain the new questions and answers for the HP HPE6-A66 exam. Every exam page will contain date at the top of the page including the updated list of exam questions and answers. Due to the authentication of current exam questions, you will pass your test in initial try.

HP HPE6-A66 Dumps Are Verified by Industry Experts

Dedication to providing the accurate Aruba Certified Design Associate Exam test questions and answers, along with brief descriptions. Every question and answer are verified through HP professionals. Highly qualified individuals who have spends many years and getting the professional experience in HP exam.
All Exam Questions Include Detailed Answers with Explanations
Instead of many other exam web portals, RealExamCollection.com deliver best HP HPE6-A66 exam questions with detailed answers explanations.

Money Back Guarantee

RealExamCollection.com is devoted to give quality HP HPE6-A66 braindumps that will assist you passing the exam and getting certification. We provide latest and realistic test questions from current exams to give you the best method of preparation for the HP HPE6-A66 exam. If you have purchased complete PDF file and unable to pass the HP exam, you can either replace your exam or claim your money back. Our money back policy is very simple, for more details visit guarantee page.

Sample Questions

Question 1

Refer to the exhibit. When planning the use of Cat7 cabling for a SmartRate connection between an ArubaOS AP and an ArubaOS switch, which sections should be considered when calculating distance? 

A. A + C
B. A + B
C. A + B + C + D
D. A + B + C

Question 2

NewStellar has a main corporate campus in a business park with two adjacent buildings that are 150 feet apart (46 meters). This is an open campus with no obstructions between the two buildings Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire building space. The ceiling for  This floor has a central main corridor with washrooms, stairs, elevators and supply, and network cabinets.There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350square feet (870 square meters).The company has determined that Wi-Fi coverage will not include the central area of each floor, whichincludes the washrooms, stairs, elevators and supply and network cabinets. Based on a capacity design,approximately how many APs should a network architect add to each floor to plan the design in VisuaiRF?

A. 40
B. 10
C. 20
D. 30

Question 3

A network architect is given the task to design a new network solution for NewStellar Company, Inc. NewSteiiar has a main corporate campus in a business park with two adjacent buildings. The network architect has given one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.  Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire buildingspace. Each floor has a central main corridor with washrooms, stairs, elevators and supply and networkcabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensionscontain 9,350 square feet {870 square meters).Because of security concerns, video cameras will be installed throughout the facility. There are 16 of these perfloor, 8 per wiring closet. The cameras are non-WiFi capable and require POE 802.3af-capable switch portsfrom which to draw power.A wireless capacity design is required. Assuming that wireless coverage is required across the Building 1,Floor 2, including the central area, and that half the required APs will connect to each wiring closet,approximately how many POE+ ports will be required per wiring closet for all devices that have POE or POE+needs?

A. 30
B. 22
C. 42
D. 8

Question 4

NewStellar has a main corporate campus in a business park with two adjacent buildings. Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total. The ceiling for each floor is 12 feet (3.6 meters) high with a drop-down ceiling at 10 feet (3 meters). The network architect has given you one floor to analyze, Building 1 Floor 2, shown in the attached exhibit. This floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet (870 square meters). Assuming that wireless coverage is not required in the central area, which square footage (square meter) value should a network architect use when determining the number of APs in a capacity design for each floor? 

A. 55.750 square feet {5,175 square meters)
B. 56.350 square feet {5,235 square meters)
C. 47.000 square feet {4,365 square meters)
D. 338,100 feet {31,410 square meters)

Question 5

A network architect is designing a new wired and wireless solution for for a company. The company has twobuildings on a campus, which each building has three floors. The campus core will be placed in the basementof Building 1. Each wiring closet has eight strands of multi-mode OM3 grade fiber that connect to a wiringcloset of the first floor of the building it is contained, referred to as a main distribution frame (MDF). Themaximum distance between a floor's wiring closet and the MDF is 100 feet (30 meters). The maximumdistance between the two MDFs and the campus core is no more than 150 feet (45 meters). There are eightstrands of multi-mode OM3 grade fiber from these two MDF closets to the campus core.Based on this information, which type of design should be used and what is the maximum speeds supported alluplinks for the existing the multi-mode fiber?

A. three-tier and 10 Gbps
B. three-tier and 40 Gbps
C. two-tier and 10 Gbps
D. two-tier and 40 Gbps